Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27.379
Filtrar
1.
Tech Coloproctol ; 28(1): 44, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561492

RESUMO

BACKGROUND: Imaging is vital for assessing rectal cancer, with endoanal ultrasound (EAUS) being highly accurate in large tertiary medical centers. However, EAUS accuracy drops outside such settings, possibly due to varied examiner experience and fewer examinations. This underscores the need for an AI-based system to enhance accuracy in non-specialized centers. This study aimed to develop and validate deep learning (DL) models to differentiate rectal cancer in standard EAUS images. METHODS: A transfer learning approach with fine-tuned DL architectures was employed, utilizing a dataset of 294 images. The performance of DL models was assessed through a tenfold cross-validation. RESULTS: The DL diagnostics model exhibited a sensitivity and accuracy of 0.78 each. In the identification phase, the automatic diagnostic platform achieved an area under the curve performance of 0.85 for diagnosing rectal cancer. CONCLUSIONS: This research demonstrates the potential of DL models in enhancing rectal cancer detection during EAUS, especially in settings with lower examiner experience. The achieved sensitivity and accuracy suggest the viability of incorporating AI support for improved diagnostic outcomes in non-specialized medical centers.


Assuntos
Aprendizado Profundo , Neoplasias Retais , Humanos , Endossonografia/métodos , Ultrassonografia/métodos , Redes Neurais de Computação , Neoplasias Retais/diagnóstico por imagem
2.
Opt Lett ; 49(7): 1725-1728, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38560847

RESUMO

Ultrasound coupling is one of the critical challenges for traditional photoacoustic (or optoacoustic) microscopy (PAM) techniques transferred to the clinical examination of chronic wounds and open tissues. A promising alternative potential solution for breaking the limitation of ultrasound coupling in PAM is photoacoustic remote sensing (PARS), which implements all-optical non-interferometric photoacoustic measurements. Functional imaging of PARS microscopy was demonstrated from the aspects of histopathology and oxygen metabolism, while its performance in hemodynamic quantification remains unexplored. In this Letter, we present an all-optical thermal-tagging flowmetry approach for PARS microscopy and demonstrate it with comprehensive mathematical modeling and ex vivo and in vivo experimental validations. Experimental results demonstrated that the detectable range of the blood flow rate was from 0 to 12 mm/s with a high accuracy (measurement error:±1.2%) at 10-kHz laser pulse repetition rate. The proposed all-optical thermal-tagging flowmetry offers an effective alternative approach for PARS microscopy realizing non-contact dye-free hemodynamic imaging.


Assuntos
Técnicas Fotoacústicas , Tecnologia de Sensoriamento Remoto , Técnicas Fotoacústicas/métodos , Reologia/métodos , Ultrassonografia/métodos , Microscopia/métodos
3.
Can J Vet Res ; 88(2): 55-65, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38595950

RESUMO

Urinary bladder volume (UBV) can be estimated using point-of-care ultrasound. The purpose of this study was to compare 2 UBV estimation methods, i.e., three-dimensional (3D) bladder circumference tracing and 2-dimensional (2D) linear bladder dimension formula, against actual bladder volumes in awake client-owned cats and identify the best scanning position for UBV estimations. Up to 3 paired sets of orthogonal longitudinal and transverse bladder ultrasound images were acquired by a trained clinician from 21 cats positioned in dorsal, right lateral, and left lateral recumbency. UBV estimation was performed with these images by 2 different observers using both methods. Actual bladder volumes were measured through urethral catheterization and compared to the estimated UBV using Lin's concordance correlation coefficient and Bland-Altman analyses. Considering all positions, both methods showed substantial strength-of-agreement with actual bladder volumes; the 3D bladder circumference method (ρc = 0.963, 95% CI: 0.952 to 0.974) with a significant median bias of -4.08 mL (P < 0.001, IQR -7.63 to -0.68 mL, LOA -48.55 to 21.75 mL) and the 2D linear dimension method (ρc = 0.974, 95% CI: 0.966 to 0.982) with a median bias of -0.82 mL (P = 0.686, IQR -3.89 to 4.05 mL, LOA -35.23 to 35.21 mL). Scanning in left lateral recumbency provided the strongest strengths-of-agreement and precision against actual bladder volumes for both methods. Regardless of scanning positions, the 2D linear dimension method is more accurate than the 3D bladder circumference method, although both methods are imprecise with increasing volumes and UBV assessment through urinary catheterization remains the gold standard.


Le volume vésical (UBV) peut être estimé à l'aide de l'échographie au point d'intervention. L'objectif de cette étude fut de comparer 2 méthodes d'estimation du UBV, i.e., le tracé tridimensionnel (3D) de la circonférence de la vessie et la formule de dimension linéaire en 2 dimensions (2D), aux volumes vésicaux réels chez des chats éveillés appartenant à des clients, ainsi que d'identifier la meilleure position de balayage pour l'estimation du UBV. Jusqu'à 3 séries appariées d'images ultrasonores longitudinales et transverses orthogonales ont été acquises par une clinicienne qualifiée sur 21 chats positionnés en décubitus dorsal, latéral droit et latéral gauche. L'estimation du UBV a été réalisée à partir de ces images par 2 observateurs différents utilisant les 2 méthodes. Les volumes vésicaux réels ont été mesurés par cathétérisme urétral et comparés aux UBV estimés à l'aide du coefficient de corrélation de concordance de Lin et d'analyses de Bland-Altman. Toutes positions confondues, les 2 méthodes ont montré une concordance considérable avec les volumes vésicaux réels; la méthode de la circonférence vésicale 3D (ρc = 0,963, 95 % CI : 0,952 à 0,974) avec un biais médian significatif de −4,08 mL (P < 0,001, IQR −7,63 à −0,68 mL, LOA −48,55 à 21,75 mL) et la méthode de la dimension linéaire 2D (ρc = 0,974, 95 % CI : 0,966 à 0,982) avec un biais médian de −0,82 mL (P = 0,686, IQR −3,89 à 4,05 mL, LOA −35,23 à 35,21 mL). Le balayage en décubitus latéral gauche a démontré les meilleures concordance et précision par rapport aux volumes vésicaux réels pour les 2 méthodes. Quelle que soit la position de balayage, la méthode de la dimension linéaire 2D est plus précise que la méthode de circonférence vésicale 3D, bien que les 2 méthodes deviennent imprécises avec des volumes vésicaux plus élevés et que l'évaluation du UBV par cathétérisme urinaire demeure l'étalon d'or.(Traduit par les auteurs).


Assuntos
Testes Imediatos , Bexiga Urinária , Gatos , Animais , Bexiga Urinária/diagnóstico por imagem , Ultrassonografia/veterinária , Ultrassonografia/métodos , Reprodutibilidade dos Testes
4.
West J Emerg Med ; 25(2): 282-290, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38596931

RESUMO

Introduction: Point-of-care ultrasound (POCUS) performed by emergency physicians (EP) has emerged as an effective alternative to radiology department ultrasounds for the diagnosis of lower extremity deep vein thrombosis (DVT). Systematic reviews suggested good sensitivity and specificity overall for EP-performed POCUS for DVT diagnosis, yet high levels of heterogeneity were reported. Methods: In this systematic review and meta-analysis, we aimed to provide the most up-to-date estimates of the accuracy of EP-performed POCUS for diagnosis of DVT and to explore potential correlations with test performance. We performed systematic searches in MEDLINE and Embase for original, primary data articles from January 2012-June 2021 comparing the efficacy of POCUS performed by EPs to the local standard. Quality Assessment of Diagnostic Accuracy Studies-2 for individual articles are reported. We obtained summary measures of sensitivity, specificity, and their corresponding 95% confidence intervals (CI) using bivariate mixed-effects regression models. We performed meta-regression, subgroup, and sensitivity analyses as planned in the protocol CRD42021268799 submitted to PROSPERO. Results: Fifteen publications fit the inclusion criteria, totaling 2,511 examinations. Pooled sensitivity and specificity were 90% (95% CI 82%-95%) and 95% (CI 91%-97%), respectively. Subgroup analyses by EP experience found significantly better accuracy for exams performed by EP specialists (93%, CI 88%-97%) vs trainees (77%, CI 60%-94%). Specificity for EP specialists (97%, CI 94%-99%) was higher than for trainees (87%, CI 76%-99%, P = 0.01). Three-point compression ultrasound (CUS) was more sensitive than two-point CUS but was only statistically significant when limited to EP specialists (92% vs 88%, P = 0.07, and 95% vs 88%, P = 0.02, respectively). Conclusion: Point-of-care ultrasound performed by emergency physicians is sensitive and specific for the diagnosis of suspected DVT when performed by trained attending EPs. Three-point compression ultrasound examination may be more sensitive than two-point CUS.


Assuntos
Médicos , Trombose Venosa , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Serviço Hospitalar de Emergência , Ultrassonografia/métodos , Sensibilidade e Especificidade , Trombose Venosa/diagnóstico por imagem
5.
Nefrología (Madrid) ; 44(2): 159-164, Mar-Abr. 2024. ilus
Artigo em Espanhol | IBECS | ID: ibc-231565

RESUMO

La hiponatremia es un trastorno multifactorial definido como una disminución en la concentración plasmática de sodio. Su diagnóstico diferencial requiere una evaluación adecuada del volumen extracelular. Sin embargo, la determinación del volumen extracelular, simplemente basada en la historia clínica, las constantes vitales, el examen físico y los hallazgos de laboratorio, conducen en ocasiones a un diagnóstico erróneo por lo que el enfoque terapéutico puede ser equivocado. El empleo de ecografía a pie de cama (Point-of-Care Ultrasound [PoCUS]), mediante la combinación de ecografía pulmonar (Lung Ultrasound [LUS]), Venous Excess UltraSound (VExUS) y la ecocardioscopia (Focused Cardiac Ultrasound [FoCUS]) permiten, en combinación con el resto de los parámetros, una valoración holística mucho más precisa del estado del volumen extracelular del paciente.(AU)


Hyponatremia is a multifactorial disorder defined as a decrease in plasma sodium concentration. Its differential diagnosis requires an adequate evaluation of the extracellular volume. However, extracellular volume determination, simply based on the clinical history, vital signs, physical examination, and laboratory findings can leads to misdiagnosis and inappropriate treatment. The use of Point-of-Care Ultrasound (PoCUS), through the combination of Lung Ultrasound (LUS), Venous Excess UltraSound (VExUS) and Focused Cardiac Ultrasound (FoCUS), allows a much more accurate holistic assessment of the patient's extracellular volume status in combination with the other parameters.(AU)


Assuntos
Humanos , Feminino , Idoso , Hiponatremia/diagnóstico , Medicina de Precisão , Diagnóstico Diferencial , Ultrassonografia/métodos , Concentração Osmolar , Pacientes Internados , Exame Físico , Avaliação de Sintomas
6.
Sci Rep ; 14(1): 7878, 2024 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-38570589

RESUMO

Thyroid nodules are a common occurrence, and although most are non-cancerous, some can be malignant. The American College of Radiology has developed the Thyroid Imaging Reporting and Data System (TI-RADS) to standardize the interpretation and reporting of thyroid ultrasound results. Within TI-RADS, a category 4 designation signifies a thyroid nodule with an intermediate level of suspicion for malignancy. Accurate classification of these nodules is crucial for proper management, as it can potentially reduce unnecessary surgeries and improve patient outcomes. This study utilized deep learning techniques to effectively classify TI-RADS category 4 thyroid nodules as either benign or malignant. A total of 500 patients were included in the study and randomly divided into a training group (350 patients) and a test group (150 patients). The YOLOv3 model was constructed and evaluated using various metrics, achieving an 84% accuracy in the classification of TI-RADS category 4 thyroid nodules. Based on the predictions of the model, along with clinical and ultrasound data, a nomogram was developed. The performance of the nomogram was superior in both the training and testing groups. Furthermore, the calibration curve demonstrated good agreement between predicted probabilities and actual outcomes. Decision curve analysis further confirmed that the nomogram provided greater net benefits. Ultimately, the YOLOv3 model and nomogram successfully improved the accuracy of distinguishing between benign and malignant TI-RADS category 4 thyroid nodules, which is crucial for proper management and improved patient outcomes.


Assuntos
Aprendizado Profundo , Paraganglioma , Neoplasias da Glândula Tireoide , Nódulo da Glândula Tireoide , Humanos , Nomogramas , Estudos Retrospectivos , Neoplasias da Glândula Tireoide/patologia , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/patologia , Ultrassonografia/métodos
7.
Zhonghua Yi Xue Za Zhi ; 104(15): 1225-1229, 2024 Apr 16.
Artigo em Chinês | MEDLINE | ID: mdl-38637160

RESUMO

Acute respiratory distress syndrome (ARDS) continues to cause significant morbidity and mortality worldwide. However, there are currently no corresponding specific medications. Lung, right heart, and diaphragm protective therapy is the cornerstone of ARDS management. Non-invasive, radiation-free, and transportation-free point-of-care ultrasound enables for real-time dynamic evaluation of the lung, right heart, and diaphragm. It is an essential tool for the diagnosis, monitoring, and clinical decision-making of ARDS patients. However, ultrasound has several limitations, and its clinical application must be carefully evaluated in conjunction with clinical symptoms and other monitoring techniques. Further research is needed to determine whether clinical decision-making based on point-of-care ultrasound examination can improve the prognosis of ARDS patients.


Assuntos
Sistemas Automatizados de Assistência Junto ao Leito , Síndrome do Desconforto Respiratório , Humanos , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Síndrome do Desconforto Respiratório/terapia , Pulmão/diagnóstico por imagem , Ultrassonografia/métodos , Prognóstico
8.
BMC Womens Health ; 24(1): 245, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637819

RESUMO

BACKGROUND: Pelvic floor myofascial pain is one of the pelvic floor dysfunction diseases disturbing women after delivery. There is a lack of objective standardization for the diagnosis of pelvic floor myofascial pain due to the various symptoms and the dependence on the palpating evaluation. Ultrasound imaging has the advantages of safety, simplicity, economy and high resolution, which makes it an ideal tool for the assistant diagnosis of pelvic floor myofascial pain and evaluation after treatment. METHODS: This is a retrospective case-control study including women accepting evaluation of pelvic floor function at 6 weeks to 1 year postpartum. They were divided into pelvic floor myofascial pain group and normal control group. A BCL 10-5 biplane transducer was applied to observed their puborectalis. The length, minimum width, area, deficiency, deficiency length, deficiency width, deficiency area, rate of deficiency area, local thickening,angle between the tendinous arch of levator ani muscle and puborectalis of corresponding puborectalis in different groups were observed and measured. RESULTS: A total of 220 postpartum women participated in the study, with 77 in the pelvic floor myofascial pain group and 143 in the normal control group. The Intraclass correlation coefficient value was over 0.750, and Kappa ranged from 0.600 to 0.800. puborectalis deficiency (adjusted odds ratio = 11.625, 95% confidence interval = 4.557-29.658) and focal thickening (adjusted odds ratio = 16.891, 95% confidence interval = 1.819-156.805) were significantly associated with higher odds of having postpartum pelvic floor myofascial pain. Grayscale or the angle between the arch tendineus levator ani and puborectalis measurements on the pain side tended to be smaller than on the non-pain side in patients with unilateral puborectalis or iliococcygeus pain (P < 0.05). CONCLUSIONS: This study demonstrated that transvaginal ultrasound was a potentially efficient technique for evaluating postpartum pelvic floor myofascial pain due to its ability to assess various sonographic characteristics of the levator ani muscles.


Assuntos
Distúrbios do Assoalho Pélvico , Diafragma da Pelve , Humanos , Feminino , Diafragma da Pelve/diagnóstico por imagem , Estudos Retrospectivos , Estudos de Casos e Controles , Período Pós-Parto , Dor , Distúrbios do Assoalho Pélvico/diagnóstico por imagem , Ultrassonografia/métodos
9.
BMC Res Notes ; 17(1): 108, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637887

RESUMO

OBJECTIVE: Considering the importance of endometriosis and its relatively high prevalence among women, this study sought to investigate clinical and Transrectal and transvaginal ultrasounds (TVS) findings of disease. METHODS: This descriptive-analytical study was performed based on medical records of 155 women with endometriosis admitted to Rasool-e Akram Hospital in Tehran for a TVS. All the sonography data and patients' information were collected into checklists and analyzed in SPSS-25 software (IBM). RESULTS: The mean age of participants was 32.4 ± 6.1 years, ranging from 18 to 50 years. Endometrioma was prevalent in 129 patients (84.8%). Size of endometrioma (diameter) was more than 3 cm in 79.9% of patients, and 3 cm or fewer in 20.1% of cases. Bladder, intestinal, vaginal, and rectosigmoid involvements with endometriosis implants were observed in 4 (2.6%), 54 (35.5), 3 (0.2%), and 51 (33.5) of patients, respectively. A total of 64.5% of patients were diagnosed with incomplete stenosis of the Douglas pouch and 35.5% had complete stenosis. Deep infiltrating endometriosis (DIE) was less than 1 cm in 20.7%, 1 to 3 cm in 42.3%, and over 3 cm in 37% of patients. The most common manifestations of endometriosis Obliteration of the Douglas pouch, endometrioma, and DIE. In addition, imaging modalities have shown promising results, indicating the necessity to use transvaginal ultrasound as the first line of diagnosis in patients with clinically suspected endometriosis.


Assuntos
Endometriose , Humanos , Feminino , Adulto , Endometriose/diagnóstico por imagem , Constrição Patológica , Sensibilidade e Especificidade , Irã (Geográfico) , Diagnóstico por Imagem , Ultrassonografia/métodos
10.
J Acoust Soc Am ; 155(4): 2670-2686, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38639562

RESUMO

Recently, ultrasound transit time spectroscopy (UTTS) was proposed as a promising method for bone quantitative ultrasound measurement. Studies have showed that UTTS could estimate the bone volume fraction and other trabecular bone structure in ultrasonic through-transmission measurements. The goal of this study was to explore the feasibility of UTTS to be adapted in ultrasonic backscatter measurement and further evaluate the performance of backscattered ultrasound transit time spectrum (BS-UTTS) in the measurement of cancellous bone density and structure. First, taking ultrasonic attenuation into account, the concept of BS-UTTS was verified on ultrasonic backscatter signals simulated from a set of scatterers with different positions and intensities. Then, in vitro backscatter measurements were performed on 26 bovine cancellous bone specimens. After a logarithmic compression of the BS-UTTS, a linear fitting of the log-compressed BS-UTTS versus ultrasonic propagated distance was performed and the slope and intercept of the fitted line for BS-UTTS were determined. The associations between BS-UTTS parameters and cancellous bone features were analyzed using simple linear regression. The results showed that the BS-UTTS could make an accurate deconvolution of the backscatter signal and predict the position and intensity of the simulated scatterers eliminating phase interference, even the simulated backscatter signal was with a relatively low signal-to-noise ratio. With varied positions and intensities of the scatterers, the slope of the fitted line for the log-compressed BS-UTTS versus ultrasonic propagated distance (i.e., slope of BS-UTTS for short) yield a high agreement (r2 = 99.84%-99.96%) with ultrasonic attenuation in simulated backscatter signal. Compared with the high-density cancellous bone, the low-density specimen showed more abundant backscatter impulse response in the BS-UTTS. The slope of BS-UTTS yield a significant correlation with bone mineral density (r = 0.87; p < 0.001), BV/TV (r = 0.87; p < 0.001), and cancellous bone microstructures (r up to 0.87; p < 0.05). The intercept of BS-UTTS was also significantly correlated with bone densities (r = -0.87; p < 0.001) and trabecular structures (|r|=0.43-0.80; p < 0.05). However, the slope of the BS-UTTS underestimated attenuation when measurements were performed experimentally. In addition, a significant non-linear relationship was observed between the measured attenuation and the attenuation estimated by the slope of the BS-UTTS. This study demonstrated that the UTTS method could be adapted to ultrasonic backscatter measurement of cancellous bone. The derived slope and intercept of BS-UTTS could be used in the measurement of bone density and microstructure. The backscattered ultrasound transit time spectroscopy might have potential in the diagnosis of osteoporosis in the clinic.


Assuntos
Osso e Ossos , Osso Esponjoso , Animais , Bovinos , Osso Esponjoso/diagnóstico por imagem , Espalhamento de Radiação , Ultrassonografia/métodos , Osso e Ossos/diagnóstico por imagem , Densidade Óssea/fisiologia , Análise Espectral/métodos
11.
Zhonghua Nei Ke Za Zhi ; 63(4): 355-364, 2024 Apr 01.
Artigo em Chinês | MEDLINE | ID: mdl-38561280

RESUMO

Ultrasound-guided thermal ablation of papillary thyroid cancer (PTC) has been promoted in clinical practice over the past few years. Thermal ablation has the advantages of being minimally invasive, effective, and safe. However, current guidelines and consensus only focus on low-risk papillary thyroid microcarcinoma. With growing clinical application and accumulating scientific research in thermal ablation for PTC, there is considerable evidence to demonstrate that thermal ablation can treat larger PTC tumors and benefit more patients with PTC. To expand the indications and standardize the technical details and perioperative patient management for PTC ablation, experts from the Society of Tumor Ablation Therapy of the Chinese Anti-Cancer Association, the Ablation Expert Committee of the Chinese Society of Clinical Oncology (CSCO), Chinese Medical Doctor Association College of Interventionalists Tumor Ablation Committee, and Chinese Bethune Spirit Research Association Endocrinology and Diabetes Branch Interventional Endocrine Committee discussed and developed a consensus on thermal ablation of PTC based on the latest research results. This consensus aims to promote the rapid development of thermal ablation for PTC in the clinic.


Assuntos
Carcinoma Papilar , Neoplasias da Glândula Tireoide , Humanos , Câncer Papilífero da Tireoide , Consenso , Neoplasias da Glândula Tireoide/cirurgia , Carcinoma Papilar/cirurgia , Ultrassonografia/métodos , Estudos Retrospectivos
12.
Eur J Med Res ; 29(1): 222, 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38581075

RESUMO

BACKGROUND: Pneumonia is a major public health problem with an impact on morbidity and mortality. Its management still represents a challenge. The aim was to determine whether a new diagnostic algorithm combining lung ultrasound (LUS) and procalcitonin (PCT) improved pneumonia management regarding antibiotic use, radiation exposure, and associated costs, in critically ill pediatric patients with suspected bacterial pneumonia (BP). METHODS: Randomized, blinded, comparative effectiveness clinical trial. Children < 18y with suspected BP admitted to the PICU from September 2017 to December 2019, were included. PCT was determined at admission. Patients were randomized into the experimental group (EG) and control group (CG) if LUS or chest X-ray (CXR) were done as the first image test, respectively. Patients were classified: 1.LUS/CXR not suggestive of BP and PCT < 1 ng/mL, no antibiotics were recommended; 2.LUS/CXR suggestive of BP, regardless of the PCT value, antibiotics were recommended; 3.LUS/CXR not suggestive of BP and PCT > 1 ng/mL, antibiotics were recommended. RESULTS: 194 children were enrolled, 113 (58.2%) females, median age of 134 (IQR 39-554) days. 96 randomized into EG and 98 into CG. 1. In 75/194 patients the image test was not suggestive of BP with PCT < 1 ng/ml; 29/52 in the EG and 11/23 in the CG did not receive antibiotics. 2. In 101 patients, the image was suggestive of BP; 34/34 in the EG and 57/67 in the CG received antibiotics. Statistically significant differences between groups were observed when PCT resulted < 1 ng/ml (p = 0.01). 3. In 18 patients the image test was not suggestive of BP but PCT resulted > 1 ng/ml, all of them received antibiotics. A total of 0.035 mSv radiation/patient was eluded. A reduction of 77% CXR/patient was observed. LUS did not significantly increase costs. CONCLUSIONS: Combination of LUS and PCT showed no risk of mistreating BP, avoided radiation and did not increase costs. The algorithm could be a reliable tool for improving pneumonia management. CLINICAL TRIAL REGISTRATION: NCT04217980.


Assuntos
Pneumonia Bacteriana , Pneumonia , Exposição à Radiação , Feminino , Humanos , Criança , Masculino , Pró-Calcitonina , Pulmão/diagnóstico por imagem , Pneumonia/diagnóstico por imagem , Pneumonia/tratamento farmacológico , Pneumonia Bacteriana/diagnóstico por imagem , Pneumonia Bacteriana/tratamento farmacológico , Ultrassonografia/métodos , Antibacterianos/uso terapêutico
13.
Clin Rheumatol ; 43(5): 1683-1692, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38568436

RESUMO

To identify the value of salivary gland ultrasound (SGUS) combined with magnetic resonance imaging (MRI) and magnetic resonance sialography (MRS) in predicting the results of labial salivary gland biopsy (LSGB) in patients with suspected primary Sjögren syndrome (pSS), and construct a nomogram model to predict LSGB results. A total of 181 patients who were admitted with suspected pSS from December 2018 to April 2023 were examined and divided into a training set (n = 120) and a validation set (n = 61). Baseline data of the two groups were examined, and the value of SGUS, MRI, and MRS in predicting LSGB was analyzed. Multivariate logistic analysis was used to screen for risk factors, and nomogram prediction models were constructed using these results. In the training set, the SGUS, MRI, and MRS scores of patients in the LSGB + group were higher than those in the LSGB - group (all P < 0.001). The positive prediction value (PPV) was 91% for an SGUS score of 3, and 82% for MRI and MRS scores of 2 or more. We developed a nomogram prediction model based on SGUS, MRI, and MRS data, and it had a concordance index (C-index) of 0.94. The Hosmer-Lemeshow test (χ2 = 3.17, P = 0.92) also indicated the nomogram prediction model had good accuracy and calibration for prediction of LSGB results. A nomogram model based on SGUS, MRI, and MRS results can help rheumatologists decide whether LSGB should be performed in patients with suspected pSS.


Assuntos
Síndrome de Sjogren , Humanos , Síndrome de Sjogren/diagnóstico por imagem , Síndrome de Sjogren/patologia , Glândulas Salivares/diagnóstico por imagem , Glândulas Salivares/patologia , Biópsia , Glândulas Salivares Menores/diagnóstico por imagem , Glândulas Salivares Menores/patologia , Ultrassonografia/métodos
14.
Front Endocrinol (Lausanne) ; 15: 1299686, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38633756

RESUMO

Objectives: To apply machine learning to extract radiomics features from thyroid two-dimensional ultrasound (2D-US) combined with contrast-enhanced ultrasound (CEUS) images to classify and predict benign and malignant thyroid nodules, classified according to the Chinese version of the thyroid imaging reporting and data system (C-TIRADS) as category 4. Materials and methods: This retrospective study included 313 pathologically diagnosed thyroid nodules (203 malignant and 110 benign). Two 2D-US images and five CEUS key frames ("2nd second after the arrival time" frame, "time to peak" frame, "2nd second after peak" frame, "first-flash" frame, and "second-flash" frame) were selected to manually label the region of interest using the "Labelme" tool. A total of 7 images of each nodule and their annotates were imported into the Darwin Research Platform for radiomics analysis. The datasets were randomly split into training and test cohorts in a 9:1 ratio. Six classifiers, namely, support vector machine, logistic regression, decision tree, random forest (RF), gradient boosting decision tree and extreme gradient boosting, were used to construct and test the models. Performance was evaluated using a receiver operating characteristic curve analysis. The area under the curve (AUC), sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy (ACC), and F1-score were calculated. One junior radiologist and one senior radiologist reviewed the 2D-US image and CEUS videos of each nodule and made a diagnosis. We then compared their AUC and ACC with those of our best model. Results: The AUC of the diagnosis of US, CEUS and US combined CEUS by junior radiologist and senior radiologist were 0.755, 0.750, 0.784, 0.800, 0.873, 0.890, respectively. The RF classifier performed better than the other five, with an AUC of 1 for the training cohort and 0.94 (95% confidence interval 0.88-1) for the test cohort. The sensitivity, specificity, accuracy, PPV, NPV, and F1-score of the RF model in the test cohort were 0.82, 0.93, 0.90, 0.85, 0.92, and 0.84, respectively. The RF model with 2D-US combined with CEUS key frames achieved equivalent performance as the senior radiologist (AUC: 0.94 vs. 0.92, P = 0.798; ACC: 0.90 vs. 0.92) and outperformed the junior radiologist (AUC: 0.94 vs. 0.80, P = 0.039, ACC: 0.90 vs. 0.81) in the test cohort. Conclusions: Our model, based on 2D-US and CEUS key frames radiomics features, had good diagnostic efficacy for thyroid nodules, which are classified as C-TIRADS 4. It shows promising potential in assisting less experienced junior radiologists.


Assuntos
Neoplasias da Glândula Tireoide , Nódulo da Glândula Tireoide , Humanos , Nódulo da Glândula Tireoide/patologia , Neoplasias da Glândula Tireoide/patologia , Estudos Retrospectivos , Curva ROC , Ultrassonografia/métodos
15.
PLoS One ; 19(4): e0300753, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38635681

RESUMO

BACKGROUND: We are obliged to give babies the chance to profit from a nationwide screening of developmental dysplasia of the hip in very rural areas of Mongolia, where trained physicians are scarce. This study aimed to compare the quality and interpretation of hip ultrasound screening examinations performed by nurses and junior physicians. METHODS: A group of 6 nurses and 6 junior physician volunteers with no previous ultrasound experience underwent Graf's standard training in hands-on practice. Newborns were examined before discharge from the hospital, according to the national guideline. Two standard documentation images of each hip were saved digitally. The groups were compared on the proportion of good quality of sonograms and correct interpretation. Two Swiss supervisors' agreed diagnosis according to Graf was considered the final reference for the study purposes. RESULTS: A total of 201 newborns (402 hips or 804 sonograms) were examined in the study, with a mean age of 1.3±0.8 days at examination. Junior physicians examined 100 newborns (200 hips or 400 sonograms), while nurses examined 101 newborns (202 hips or 404 sonograms). The study subjects of the two groups were well balanced for the distribution of baseline characteristics. The study observed no statistically significant difference in the quality of Graf's standard plane images between the providers. Eventually, 92.0% (92) of the physician group and 89.1% (90) of the nurse group were correctly diagnosed as "Group A" (Graf's Type 1 hip) or "Non-Group A" hips (p = 0.484). The most common errors among the groups were a missing lower limb, wrong measurement lines, and technical problems. CONCLUSION: Our study provides evidence that while there might be a trend of slightly more technical mistakes in the nurse group, the overall diagnosis accuracy is similar to junior physicians after receiving standard training in Graf's hip ultrasound method. However, after basic training, regular quality control is a must and all participants should receive refresher trainings. More specifically, nurses need training in the identification of anatomical structures.


Assuntos
Displasia do Desenvolvimento do Quadril , Luxação Congênita de Quadril , Lactente , Humanos , Recém-Nascido , Luxação Congênita de Quadril/diagnóstico por imagem , Ultrassonografia/métodos , Triagem Neonatal/métodos , Articulação do Quadril/diagnóstico por imagem
16.
Sci Rep ; 14(1): 9063, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38643221

RESUMO

Vaginal laxity (VL) is a common condition among multiparous women, especially those who have delivered vaginally. Since pelvic floor muscles (PFMs) work synergistically with other core muscles, physical therapy protocols that aim to treat VL should train the PFMs in combination with other core muscles. To investigate the activity of core muscles in multiparous women with and without VL, and its relation to sexual function. An observational, cross-sectional study. The study included 100 multiparous women, who were divided into two groups according to their scores on the vaginal laxity questionnaire (VLQ). Women who scored between 1 and 3 on the VLQ were categorized as having VL (n = 48), while those who scored between 5 and 7 were placed in the control group (n = 52). The primary outcomes were PFM displacement, diaphragmatic excursion, transversus abdominis activation ratio, and lumbar multifidus thickness measured by ultrasound imaging. The secondary outcome was sexual functioning, evaluated using the Arabic female sexual function index (ArFSFI). The VL group had significantly lower PFM displacement (mean difference (MD) - 0.42; 95% confidence interval (CI) - 0.49 to - 0.33; p = 0.001), diaphragmatic excursion (MD - 2.75; 95% CI - 2.95 to - 2.55; p = 0.001), lumbar multifidus thickness (MD - 10.08; 95% CI - 14.32 to - 5.82; p = 0.02), and ArFSFI scores (MD - 9.2; 95% CI - 10.59 to - 7.81; p = 0.001) in comparison to the control group (p < 0.05). Nevertheless, the transversus abdominis activation ratio demonstrated no significant difference between the two groups (MD 0.06; 95% CI - 0.05 to 0.17; p = 0.33). Multiparous women with VL had significantly lower PFM displacement, diaphragmatic excursion, lumbar multifidus thickness, and sexual function index scores than women in the control group. The only exception was transversus abdominis activation, which did not differ significantly between the VL and control groups.


Assuntos
Músculos Abdominais , Diafragma da Pelve , Gravidez , Humanos , Feminino , Estudos Transversais , Diafragma da Pelve/fisiologia , Músculos Abdominais/diagnóstico por imagem , Músculos Abdominais/fisiologia , Contração Muscular/fisiologia , Paridade , Ultrassonografia/métodos
17.
Nat Commun ; 15(1): 2932, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38575577

RESUMO

Ultrasound localization microscopy (ULM) enables deep tissue microvascular imaging by localizing and tracking intravenously injected microbubbles circulating in the bloodstream. However, conventional localization techniques require spatially isolated microbubbles, resulting in prolonged imaging time to obtain detailed microvascular maps. Here, we introduce LOcalization with Context Awareness (LOCA)-ULM, a deep learning-based microbubble simulation and localization pipeline designed to enhance localization performance in high microbubble concentrations. In silico, LOCA-ULM enhanced microbubble detection accuracy to 97.8% and reduced the missing rate to 23.8%, outperforming conventional and deep learning-based localization methods up to 17.4% in accuracy and 37.6% in missing rate reduction. In in vivo rat brain imaging, LOCA-ULM revealed dense cerebrovascular networks and spatially adjacent microvessels undetected by conventional ULM. We further demonstrate the superior localization performance of LOCA-ULM in functional ULM (fULM) where LOCA-ULM significantly increased the functional imaging sensitivity of fULM to hemodynamic responses invoked by whisker stimulations in the rat brain.


Assuntos
Aprendizado Profundo , Microscopia , Ratos , Animais , Microscopia/métodos , Microbolhas , Ultrassonografia/métodos , Microscopia Intravital , Microvasos/diagnóstico por imagem
18.
Respir Res ; 25(1): 135, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38509592

RESUMO

INTRODUCTION: Computed tomography (CT) is routinely employed on the evaluation of dyspnea, yet limited data exist on its assessment of diaphragmatic muscle. This study aimed to determine the capability of CT in identifying structural changes in the diaphragm among patients with ultrasound-confirmed diaphragmatic dysfunction. METHODS: Diaphragmatic ultrasounds conducted between 2018 and 2021 at our center in Marseille, France, were retrospectively collected. Diaphragmatic pillars were measured on CT scans at the L1 level and the celiac artery. Additionally, the difference in height between the two diaphragmatic domes in both diaphragmatic dysfunction cases and controls was measured and compared. RESULTS: A total of 65 patients were included, comprising 24 with diaphragmatic paralysis, 13 with diaphragmatic weakness, and 28 controls. In the case group (paralysis and weakness) with left dysfunctions (n = 24), the CT thickness of the pillars at the level of L1 and the celiac artery was significantly thinner compared with controls (2.0 mm vs. 7.4 mm and 1.8 mm vs. 3.1 mm, p < 0.001 respectively). Significantly different values were observed for paralysis (but not weakness) in the right dysfunction subgroup (n = 15) (2.6 mm vs. 7.4 mm and 2.2 mm vs. 3.8 mm, p < 0.001 respectively, for paralysis vs. controls). Regardless of the side of dysfunction, a significant difference in diaphragmatic height was observed between cases and controls (7.70 cm vs. 1.16 cm and 5.51 cm vs. 1.16 cm, p < 0.001 for right and left dysfunctions, respectively). Threshold values determined through ROC curve analyses for height differences between the two diaphragmatic domes, indicative of paralysis or weakness in the right dysfunctions, were 4.44 cm and 3.51 cm, respectively. Similarly for left dysfunctions, the thresholds were 2.70 cm and 2.48 cm, respectively, demonstrating good performance (aera under the curve of 1.00, 1.00, 0.98, and 0.79, respectively). CONCLUSION: In cases of left diaphragmatic dysfunction, as well as in paralysis associated with right diaphragmatic dysfunction, CT revealed thinner pillars. Additionally, a notable increase in the difference in diaphragmatic height demonstrated a strong potential to identify diaphragmatic dysfunction, with specific threshold values.


Assuntos
Diafragma , Debilidade Muscular , Humanos , Diafragma/diagnóstico por imagem , Estudos Retrospectivos , Ultrassonografia/métodos , Paralisia , Tomografia Computadorizada por Raios X , Tomografia
19.
World J Gastroenterol ; 30(7): 705-713, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38515948

RESUMO

BACKGROUND: The detection rate of peptic ulcer in children is improving, with development of diagnostic procedures. Gastroscopy is the gold standard for the diagnosis of peptic ulcer, but it is an invasive procedure. Gastrointestinal contrast-enhanced ultrasonography (CEUS) has the advantages of being painless, noninvasive, nonradioactive, easy to use, and safe. AIM: To investigate the clinical value of CEUS for diagnosis and treatment of peptic ulcer in children. METHODS: We investigated 43 children with digestive tract symptoms in our hospital from January 2021 to June 2022. All children were examined by routine ultrasound, gastrointestinal CEUS, and gastroscopy. The pathological results of gastroscopy were taken as the gold standard. Routine ultrasonography was performed before gastrointestinal CEUS. Conventional ultrasound showed the thickness of the gastroduodenal wall, gastric peristalsis, and the adjacent organs and tissues around the abdominal cavity. Gastrointestinal CEUS recorded the thickness of the gastroduodenal wall; the size, location and shape of the ulcer; gastric peristalsis; and adjacent organs and tissues around the abdominal cavity. The results of routine ultrasound and gastrointestinal ultrasound were compared with those of gastroscopy to evaluate the diagnostic results and coincidence rate of routine ultrasound and gastrointestinal CEUS. All children received informed consent from their guardians for CEUS. This study was reviewed and approved by the hospital medical ethics committee. RESULTS: Among the 43 children, 17 (15 male, 2 female) were diagnosed with peptic ulcer by gastroscopy. There were 26 children with nonpeptic ulcer. There were eight cases of peptic ulcer and 35 of nonpeptic ulcer diagnosed by conventional ultrasound. The diagnostic coincidence rate of peptic ulcer in children diagnosed by conventional ultrasound was 79.1% (34/43), which was significantly different from that of gastroscopy (P = 0.033). It indicates that the coincidence rate of gastrointestinal contrast-enhanced ultrasound and gastroscope is low. Fifteen cases of peptic ulcer and 28 of nonpeptic ulcer were diagnosed by CEUS. The diagnostic coincidence rate of peptic ulcer in children was 95.3% (41/43). There was no significant difference between CEUS and gastroscopy (P = 0.655). It indicates that the coincidence rate of gastrointestinal contrast-enhanced ultrasound and gastroscope is high. CONCLUSION: Gastrointestinal CEUS has a high coincidence rate in the diagnosis of peptic ulcer in children, and can be used as a preliminary examination method.


Assuntos
Meios de Contraste , Úlcera Péptica , Criança , Humanos , Masculino , Feminino , Úlcera , Úlcera Péptica/diagnóstico por imagem , Úlcera Péptica/terapia , Ultrassonografia/métodos
20.
Sensors (Basel) ; 24(6)2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38544196

RESUMO

The measurement of bladder volume is crucial for the diagnosis and treatment of urinary system diseases. Ultrasound imaging, with its non-invasive, radiation-free, and repeatable scanning capabilities, has become the preferred method for measuring residual urine volume. Nevertheless, it still faces some challenges, including complex imaging methods leading to longer measurement times and lower spatial resolution. Here, we propose a novel three-point localization method that does not require ultrasound imaging to calculate bladder volume. A corresponding triple-element ultrasound probe has been designed based on this method, enabling the ultrasound probe to transmit and receive ultrasound waves in three directions. Furthermore, we utilize the Hilbert Transform algorithm to extract the envelope of the ultrasound signal to enhance the efficiency of bladder volume measurements. The experiment indicates that bladder volume estimation can be completed within 5 s, with a relative error rate of less than 15%. These results demonstrate that this novel three-point localization method offers an effective approach for bladder volume measurement in patients with urological conditions.


Assuntos
Algoritmos , Bexiga Urinária , Humanos , Bexiga Urinária/diagnóstico por imagem , Ultrassonografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...